• LIIP Admin. Bldg., LIIP, Mamplasan, Biñan, Laguna, Philippines

Ambient Air Quality and Noise Monitoring(Ambient Monitoring)

Air Analyses (Stationary Source Emissions, Ambient Air)

  • NAAQS (National Ambient Air Quality Standards)
  • NAAQGV (National Ambient Air Quality Guideline Values)
post-image

On-site testing of air emissions which involves samples collection and on-site measurements from general environment (ambient) and on-site noise measurements with optional data-logging services.

The Philippines has established an air ambient monitoring program to continuously monitor the quality of air in the country. The program is implemented by the Department of Environment and Natural Resources (DENR) through its Environmental Management Bureau (EMB). The objective of the program is to provide timely and accurate information on the state of air quality in different regions of the country to help protect public health and the environment.

Under the air ambient monitoring program, the DENR-EMB operates monitoring stations across the country to collect data on air quality. The stations use specialized equipment to measure the concentrations of various pollutants in the air, such as particulate matter, sulfur dioxide, nitrogen dioxide, and ozone. The data collected from the monitoring stations is analyzed and used to generate air quality indices that provide information on the current state of air quality in the region.

The air ambient monitoring program in the Philippines has helped to raise public awareness about the importance of air quality and has provided valuable information to policymakers to develop strategies to mitigate air pollution. The program has also helped to identify areas where air quality is poor, leading to targeted interventions to reduce pollution levels and protect public health and the environment. Overall, the air ambient monitoring program in the Philippines is an important tool in the country's efforts to ensure clean air for its citizens.

Ambient Air Quality and Noise Monitoring (Ambient Monitoring)

Parameter Test Reference
Ammonia (NH3) MASA Method 401 (Indophenol Method)
Arsenic (As) 40 CFR Part 50, Appendix B + MASA Method 303A
Antimony (Sb) 40 CFR Part 50, Appendix B + MASA Method 303A
Asbestos NIOSH 7400 (A Rules) [adapted]
Cadmium (Cd) 40 CFR Part 50, Appendix B + MASA Method 303A
Carbon Monoxide (CO) Direct readout instrumentation / 40 CFR Part 50, Appendix C
Carbon Disulfide (CS2) US EPA Compendium Method TO-15
Chlorine and Chlorine Compounds (Cl2) MASA Method 202 (Methyl Orange Method)
Formaldehyde (HCHO) MASA Method 117 (MBTH Colorimetric Method)
Hydrogen Chloride (HCl) OSHA ID-174SG [adapted]
Hydrogen Sulfide (H2S) MASA Method 701 (Methylene Blue Colorimetry Method)
Lead (Pb) 40 CFR Part 50, Appendix G
Nitric Acid (HNO3) OSHA ID-165SG [adapted]
Nitrogen Dioxide (NO2) MASA Method 406 (Griess-Saltzman Method)
Particulate Matter 2.5 microns (PM2.5) 40 CFR Part 50, Appendix L
Particulate Matter 10 microns (PM10) 40 CFR Part 50, Appendix J
Phenol NIOSH 3502 [adapted]
Photochemical Oxidants (as Ozone) 40 CFR Part 50, Appendix D / MASA Method 411 (NBKI Method)
Sulfur Dioxide (SO2) 40 CFR Part 50, Appendix A-2 / MASA Method 704A (Pararosaniline Method)
Sulfuric Acid (H2SO4) OSHA ID-165SG [adapted]
Total Suspended Particulates (TSP) 40 CFR Part 50, Appendix B

Parameter Test Reference
BTEX (benzene, ethylbenzene, toluene, xylenes) US EPA Method TO-15 / US EPA Method TO-17
Fixed Gases (CO, CO2, H2, N2, O2, etc.) ASTM D1945
Hydrocarbons (carbon chain, C2 – C12) US EPA Method TO-3
Metals (Al, Sb, As, Ba, Be, Cd, Ca, Cr, Co, Cu, Fe, Pb, Li, Mg, Mn, Mo, Ni, K, P, Se, Ag, Na, Sr, Tl, Sn, Ti, V and Zn) 40 CFR Part 50, Appendix B + MASA Method 303A (high volume air filtration)
Methane and Natural Gases (CH4, etc.) ASTM D1945 / ASTM D1946
Pesticides and Polychlorinated Biphenyls (PCBs) US EPA Method TO-4A
Polychlorinated, Polybrominated and Brominated/Chlorinated Dibenzo-p-Dioxins and Dibenzofurans (dioxins and furans) US EPA Method TO-9A
Polycyclic Aromatic Hydrocarbons (PAHs) US EPA Method TO-13A
Volatile Organic Compounds (VOCs) US EPA Method TO-15 / US EPA Method TO-17

Parameter Test Reference
Noise Direct readout instrumentation

Interested with this service.